TOOLS

Screw pumps

18 models in this family, 149 published parameters, each carrying the source key and the page it was read on.

Back to the selector, which answers across all 333 models and 14 families.

iF1800 500 l/s Nominal displacement speed, down to 8.0×10⁻⁴ mbar drypump-edwards-if1800 +7 parameters

Edwards, screw.

ambient temp range 5 to 40 °C drypump-edwards-if1800

Read on drypump-edwards-if1800.

Read on drypump-edwards-if1800.

max inlet pressure continuous Atmospheric drypump-edwards-if1800

Read on drypump-edwards-if1800.

noise level <64 dB(A) (50Hz), <69 dB(A) drypump-edwards-if1800

Read on drypump-edwards-if1800.

power max 11.4 kW (200-208 V 50 Hz), 12.1 kW (200-208 V 60 Hz), 12.1 kW (440V drypump-edwards-if1800

Read on drypump-edwards-if1800.

pumping speed nominal 1720 m3 h-1 @ 50 Hz, 1800 m3 h-1 @ 60 Hz m3 h-1 drypump-edwards-if1800

Read on drypump-edwards-if1800 p. 19. Served to the builder as 500 l/s, read from 1800 m3 h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure restated in a second unit, 1.6x apart 8 x 10-4 mbar (50Hz), 5 x 10-4 mbar drypump-edwards-if1800

Read on drypump-edwards-if1800.

DS 2000 G 379 l/s Nominal displacement speed, down to 3.0×10⁻³ mbar drypump-busch-ds0080-2000g +8 parameters

Busch, screw.

ambient temp range 32 - 104 °F drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

exhaust pressure max 0.2 bar drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

inlet flange DN 160 ISO K drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

Read on drypump-busch-ds0080-2000g.

pumping speed nominal 1365 (790) m3/h (cfm) drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g. Served to the builder as 379 l/s, read from 1365 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required Nitrogen requirement approx. 0-75 l/ min drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

service interval 16 000 hours of operation, at the latest after 4 years drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

ultimate pressure 2.25 x 10-3 Torr drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

DRYVAC DV 1200 347 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-leybold-dryvac-dv450-1200 +11 parameters

Leybold, screw.

ambient temp range +5 to +50 °C drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

exhaust pressure max +200 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

inlet flange DN 100 ISO-K drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

max inlet pressure continuous 1,050 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

noise level 67 dB(A) drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

pumping speed nominal 1250 m3/h drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200. Served to the builder as 347 l/s, read from 1250 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval 1 year drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

ultimate pressure stated as a bound < 5 x 10-3 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

DS 1000 G 215 l/s Nominal displacement speed, down to 3.0×10⁻³ mbar drypump-busch-ds0080-2000g +8 parameters

Busch, screw.

ambient temp range 32 - 104 °F drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

exhaust pressure max 0.2 bar drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

inlet flange DN 100 ISO K drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

Read on drypump-busch-ds0080-2000g.

pumping speed nominal 775 (447) m3/h (cfm) drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g. Served to the builder as 215 l/s, read from 775 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required Nitrogen requirement approx. 0-75 l/ min drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

service interval 16 000 hours of operation, at the latest after 4 years drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

ultimate pressure 2.25 x 10-3 Torr drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

DRYVAC DV 650 181 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-leybold-dryvac-dv450-1200 +11 parameters

Leybold, screw.

ambient temp range +5 to +50 °C drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

exhaust pressure max +200 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

inlet flange DN 100 ISO-K drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

max inlet pressure continuous 1,050 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

noise level 67 dB(A) drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

pumping speed nominal 650 m3/h drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200. Served to the builder as 181 l/s, read from 650 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval 1 year drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

ultimate pressure stated as a bound < 5 x 10-3 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

DRYVAC DV 650-r 181 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-leybold-dryvac-dv450-1200 +11 parameters

Leybold, screw.

ambient temp range +5 to +50 °C drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

exhaust pressure max +200 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

inlet flange DN 100 ISO-K drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

max inlet pressure continuous 1,050 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

noise level 67 dB(A) drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

pumping speed nominal 650 m3/h drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200. Served to the builder as 181 l/s, read from 650 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval 1 year drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

ultimate pressure stated as a bound < 5 x 10-3 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

SCREWLINE SP 630 175 l/s Nominal displacement speed drypump-leybold-screwline-630 +11 parameters

Leybold, screw.

ambient temp range 10 to 40 °C drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

exhaust pressure max The pressure in the discharge line must not exceed atmospheric pressure by 200 mbar max. drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

inlet flange EN 1092-2 - PN 6 - DN 100 drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

Read on drypump-leybold-screwline-630.

max inlet pressure continuous pamb +55 mbar drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

noise level ≤ 72 dB (A) drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

Read on drypump-leybold-screwline-630.

pumping speed nominal 630 m3·h-1 (±10 %) drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630. Served to the builder as 175 l/s, read from 630 m3·h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required no (standard applications) drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

service interval Oil change and oil filter change: at the latest after 20,000 h or 2.5 years drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

ultimate pressure ≤ 0.01 mbar drypump-leybold-screwline-630

Read on drypump-leybold-screwline-630.

DS 0600 E 167 l/s Nominal displacement speed, down to 3.0×10⁻² mbar drypump-busch-ds0600e +9 parameters

Busch, screw.

ambient temp range 0-40 (32-104) °C (°F) drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

exhaust pressure max 0,2 bar drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

mass 745 kg drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

noise level 68 dB(A) drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

power max 15,0 kW drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

pumping speed nominal 600 (350) m3/h (cfm) drypump-busch-ds0600e

Read on drypump-busch-ds0600e. Served to the builder as 167 l/s, read from 600 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required Nitrogen requirement approx. 0 - 200 l/ min drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

service interval 16 000 hours of operation, at the latest after 4 years drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

ultimate pressure 3,0 x 10-2 mbar drypump-busch-ds0600e

Read on drypump-busch-ds0600e.

DS 0700 G 139 l/s Nominal displacement speed, down to 3.0×10⁻³ mbar drypump-busch-ds0080-2000g +7 parameters

Busch, screw.

exhaust pressure max 0.2 bar drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

inlet flange DN 63 ISO K drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

Read on drypump-busch-ds0080-2000g.

pumping speed nominal 500 (290) m3/h (cfm) drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g. Served to the builder as 139 l/s, read from 500 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required Nitrogen requirement approx. 0-75 l/ min drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

service interval 16 000 hours of operation, at the latest after 4 years drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

ultimate pressure 2.25 x 10-3 Torr drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

DRYVAC DV 450 125 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-leybold-dryvac-dv450-1200 +11 parameters

Leybold, screw.

ambient temp range +5 to +50 °C drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

exhaust pressure max +200 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

inlet flange DN 100 ISO-K drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

max inlet pressure continuous 1,050 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

noise level 67 dB(A) drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

pumping speed nominal 450 m3/h drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200. Served to the builder as 125 l/s, read from 450 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval 1 year drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

ultimate pressure stated as a bound < 5 x 10-3 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

DRYVAC DV 450-r 125 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-leybold-dryvac-dv450-1200 +11 parameters

Leybold, screw.

ambient temp range +5 to +50 °C drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

exhaust pressure max +200 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

inlet flange DN 100 ISO-K drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

max inlet pressure continuous 1,050 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

noise level 67 dB(A) drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

pumping speed nominal 450 m3/h drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200. Served to the builder as 125 l/s, read from 450 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval 1 year drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

Read on drypump-leybold-dryvac-dv450-1200.

ultimate pressure stated as a bound < 5 x 10-3 mbar drypump-leybold-dryvac-dv450-1200

Read on drypump-leybold-dryvac-dv450-1200.

ScrewLine SP 250 91.7 l/s Nominal displacement speed drypump-leybold-screwline-250 +11 parameters

Leybold, screw.

ambient temp range 10 to 40 °C drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

exhaust pressure max + 200 mbar/- 50 mbar with reference to atmospheric pressure drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

inlet flange DN 63 ISO-K drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

Read on drypump-leybold-screwline-250.

max inlet pressure continuous 1030 mbar drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

noise level ≤ 75 dB (A) drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

power max 7.5 kW (50 Hz), 12 kW drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

pumping speed nominal 270 m3 x h-1 @ 50 Hz, 330 m3 x h-1 @ 60 Hz m3 x h-1 drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250 p. 13. Served to the builder as 91.7 l/s, read from 330 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required no (standard applications) drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

service interval Oil change and oil filter change (once per year) drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

ultimate pressure ≤ 0.01 mbar (50 Hz), ≤ 0.005 mbar drypump-leybold-screwline-250

Read on drypump-leybold-screwline-250.

DS 0160 G 38.9 l/s Nominal displacement speed, down to 3.0×10⁻² mbar drypump-busch-ds0080-2000g +7 parameters

Busch, screw.

exhaust pressure max 0.2 bar drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

inlet flange DN 50 ISO KF drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

Read on drypump-busch-ds0080-2000g.

pumping speed nominal 140 (82) m3/h (cfm) drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g. Served to the builder as 38.9 l/s, read from 140 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required Nitrogen requirement approx. 0-75 l/ min drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

service interval 16 000 hours of operation, at the latest after 4 years drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

ultimate pressure 2.25 x 10-2 Torr drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

IPUP E100L 29.2 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-edwards-ipup +6 parameters

Edwards, screw.

ambient temp range 5 to 50 oC drypump-edwards-ipup

Read on drypump-edwards-ipup.

mass 112 kg drypump-edwards-ipup

Read on drypump-edwards-ipup.

noise level <56 dBA drypump-edwards-ipup

Read on drypump-edwards-ipup.

power max 2.8 kW drypump-edwards-ipup

Read on drypump-edwards-ipup.

pumping speed nominal 105 m3/hr drypump-edwards-ipup

Read on drypump-edwards-ipup. Served to the builder as 29.2 l/s, read from 105 m3/hr. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure 5x10-3 (3.75 x 10-3 torr) mbar drypump-edwards-ipup

Read on drypump-edwards-ipup.

IPUP E100L (Hardwire) 29.2 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-edwards-ipup +6 parameters

Edwards, screw.

ambient temp range 5 to 50 oC drypump-edwards-ipup

Read on drypump-edwards-ipup.

mass 112 kg drypump-edwards-ipup

Read on drypump-edwards-ipup.

noise level <56 dBA drypump-edwards-ipup

Read on drypump-edwards-ipup.

power max 2.8 kW drypump-edwards-ipup

Read on drypump-edwards-ipup.

pumping speed nominal 105 m3/hr drypump-edwards-ipup

Read on drypump-edwards-ipup. Served to the builder as 29.2 l/s, read from 105 m3/hr. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure 5x10-3 (3.75 x 10-3 torr) mbar drypump-edwards-ipup

Read on drypump-edwards-ipup.

IPUP E100Li 29.2 l/s Nominal displacement speed, down to 5.0×10⁻³ mbar drypump-edwards-ipup +6 parameters

Edwards, screw.

ambient temp range 5 to 50 oC drypump-edwards-ipup

Read on drypump-edwards-ipup.

mass 112 kg drypump-edwards-ipup

Read on drypump-edwards-ipup.

noise level <56 dBA drypump-edwards-ipup

Read on drypump-edwards-ipup.

power max 2.8 kW drypump-edwards-ipup

Read on drypump-edwards-ipup.

pumping speed nominal 105 m3/hr drypump-edwards-ipup

Read on drypump-edwards-ipup. Served to the builder as 29.2 l/s, read from 105 m3/hr. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure 5x10-3 (3.75 x 10-3 torr) mbar drypump-edwards-ipup

Read on drypump-edwards-ipup.

DS 0080 G 19.4 l/s Nominal displacement speed, down to 3.0×10⁻² mbar drypump-busch-ds0080-2000g +7 parameters

Busch, screw.

exhaust pressure max 0.2 bar drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

inlet flange DN 40 ISO KF drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

Read on drypump-busch-ds0080-2000g.

pumping speed nominal 70 (40) m3/h (cfm) drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g. Served to the builder as 19.4 l/s, read from 70 m3/h. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required Nitrogen requirement approx. 0-75 l/ min drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

service interval 16 000 hours of operation, at the latest after 4 years drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

ultimate pressure 2.25 x 10-2 Torr drypump-busch-ds0080-2000g

Read on drypump-busch-ds0080-2000g.

1 model the base carries no usable ultimate pressure for

They are in the corpus and they are named here. What is missing is a published value to judge them on, which is not the same as a model that fails. Not one of them reaches a servable ultimate pressure, and each names its own reason for pumping speed below: a key never printed for it, a printed reading this export cannot turn into one served figure, or a reading this export withholds.

  • SCREWLINE SP 630 F Leybold 1 parameter no pumping speed published under any key
The 7 documents this family reads
  1. drypump-busch-ds0080-2000g Installation and Maintenance Instructions Screw Vacuum Pumps COBRA DS 0080 - 2000 G Busch Manufacturing Korea, Ltd. 189-51, Soicheon-ro, Majang-myun Busch https://www.ptb-sales.com/manuals/busch/ds0080-2000g.pdf
  2. drypump-busch-ds0600e Installation and Maintenance Instructions Screw Vacuum Pumps COBRA DS 0600 E Standard version Busch Manufacturing Korea, Ltd. 189-51, Soicheon-ro, Majang-myun Busch https://www.ptb-sales.com/manuals/busch/ds0600e.pdf
  3. drypump-edwards-if1800 A533-23-880 Issue C Original Instruction Manual iF1800 Rapid Loadlock Dry Pumping Systems We, Edwards, Manor Royal, Crawley, West Sussex, RH10 9LW, UK Edwards https://www.ptb-sales.com/manuals/edwards/if1800.pdf
  4. drypump-edwards-ipup A535-72-880 Issue F (v2.1) Original Instruction Manual IPUP E100 (v2.1) Description Electrical supply BOC Edward’s Applied Material’s Edwards https://www.ptb-sales.com/manuals/edwards/ipup.pdf
  5. drypump-leybold-dryvac-dv450-1200 DRYVAC DV 450, DV 650, DV 1200 Dry Compressing Vacuum Pumps Operating Instructions 300314330_002_B1 Part Numbers 112045V07-1 /09-1 /15-1 /19-1 Leybold https://www.ptb-sales.com/manuals/leybold/dryvac-dv450-1200.pdf
  6. drypump-leybold-screwline-250 OPERATING INSTRUCTIONS GA02412_0202 ScrewLine SP 250 Dry Compressing Vacuum Pump P/N 115 001 115 002 115 003 115 004 115 005 vacuum Leybold https://www.ptb-sales.com/manuals/leybold/screwline-250.pdf
  7. drypump-leybold-screwline-630 SCREWLINE SP 630, SP 630 F Dry Compressing Screw Vacuum Pump Operating Instructions GA02411_002_C0 P/N 117 007, 117 008 117 105 - 117 108 Leybold https://www.ptb-sales.com/manuals/leybold/screwline-630.pdf