TOOLS

ion star pumps

7 models in this family, 66 published parameters, each carrying the source key and the page it was read on.

Back to the selector, which answers across all 333 models and 14 families.

VacIon Plus 500 StarCell410 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-500-manual-idealvac+11 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 °Cagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 43.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 85.

inlet flange8” CFF (NW 150) AISI 304 ESRagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

operating life at reference pressure80000 hoursagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53. Served to the builder as 410 l/s. Export rule: published nitrogen pumping speed.

starting pressure max≤1x10-2 mbaragilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

ultimate pressurestated as a boundBelow 10-11 mbaragilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

VacIon Plus 300 StarCell240 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-300+13 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 °Cagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 5.

bake temp max with magnets150 to 220 °Cagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 36.

cathode materialTitaniumagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

Read on agilent-vacion-plus-300 p. 46.

inlet flange8" CFF (NW 150) AISI 304 ESRagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

magnet typeFerriteagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

Read on agilent-vacion-plus-300 p. 15.

operating life at reference pressure80000 hoursagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

pumping speed n2240 l/sagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15. Served to the builder as 240 l/s. Export rule: published nitrogen pumping speed.

service intervalmaintenance free (aucun intervalle chiffre)agilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 39.

starting pressure maxd1x10-2 mbaragilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

ultimate pressurestated as a boundBelow 10-11 mbaragilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

voltage-7000 Vdcagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

VacIon Plus 150 StarCell125 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-150-manual-idealvac+10 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 Cagilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 4.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 42.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

operating life at reference pressure80000 hoursagilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 15. Served to the builder as 125 l/s. Export rule: published nitrogen pumping speed.

starting pressure max≤ 1 x 10^-2 mbaragilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

VacIon Plus 75 StarCell65 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 °Cagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 4.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 17.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16. Served to the builder as 65 l/s. Export rule: published nitrogen pumping speed.

starting pressure max5 x 10^-2 Torragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 13.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

VacIon Plus 55 StarCell50 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 °Cagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 4.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 17.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16. Served to the builder as 50 l/s. Export rule: published nitrogen pumping speed.

starting pressure max5 x 10^-2 Torragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 13.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

VacIon Plus 40 StarCell34 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 °Cagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 4.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 17.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16. Served to the builder as 34 l/s. Export rule: published nitrogen pumping speed.

starting pressure max5 x 10^-2 Torragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 13.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

VacIon Plus 20 StarCell20 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-20-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion star.

ambient temp range0 to +85 Cagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 5.

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

magnet typeFerrite or Sm-Coagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

operating life at reference pressure80000 hoursagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

Read on agilent-vacion-plus-20-manual-idealvac p. 15. Served to the builder as 20 l/s. Export rule: published nitrogen pumping speed.

starting pressure max≤ 5 x 10^-2 mbaragilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

The 5 documents this family reads
  1. agilent-vacion-plus-150-manual-idealvac VacIon Plus 150 pumps Instruction Manual (87-900-102-01 (E)) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-150-Ion-Pumps-Manual.pdf
  2. agilent-vacion-plus-20-manual-idealvac VacIon Plus 20 pumps User Manual (87-900-106-01 (E)) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-Plus-20-Ion-Pumps-Manual.pdf
  3. agilent-vacion-plus-300 VacIon Plus 300 pumps User Manual (87-900-103-01 (F), 05/2011) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-300-Ion-Pumps-Manual.pdf
  4. agilent-vacion-plus-40-55-75-manual-idealvac VacIon Plus 40/55/75 pumps User Manual (87-900-105-01 (E)) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-Plus-40-55-75-Ion-Pumps-Manual.pdf
  5. agilent-vacion-plus-500-manual-idealvac VacIon Plus 500 pumps User Manual / 87-900-104-01 (F) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/ManualsII/Agilent_VacIon_Plus_500_Pumps_Manual.pdf