VacIon Plus 500 Noble Diode440 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-500-manual-idealvac+11 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 °Cagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 43.

cathode materialTitanium/Tantalumagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 85.

inlet flange8” CFF (NW 150) AISI 304 ESRagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

operating life at reference pressure50000 hoursagilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53. Served to the builder as 440 l/s. Export rule: published nitrogen pumping speed.

starting pressure max≤1x10-3 mbaragilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

ultimate pressurestated as a boundBelow 10-11 mbaragilent-vacion-plus-500-manual-idealvac

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

Read on agilent-vacion-plus-500-manual-idealvac p. 53.

VacIon Plus 300 Noble Diode260 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-300+13 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 °Cagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 5.

bake temp max with magnets150 to 220 °Cagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 36.

cathode materialTitanium/Tantalumagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

Read on agilent-vacion-plus-300 p. 46.

inlet flange8" CFF (NW 150) AISI 304 ESRagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

magnet typeFerriteagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

Read on agilent-vacion-plus-300 p. 15.

operating life at reference pressure50000 hoursagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

pumping speed n2260 l/sagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15. Served to the builder as 260 l/s. Export rule: published nitrogen pumping speed.

service intervalmaintenance free (aucun intervalle chiffre)agilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 39.

starting pressure maxd1x10-3 mbaragilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

ultimate pressurestated as a boundBelow 10-11 mbaragilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

voltage+7000 Vdcagilent-vacion-plus-300

Read on agilent-vacion-plus-300 p. 15.

VacIon Plus 150 Noble Diode135 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-150-manual-idealvac+10 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 Cagilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 4.

cathode materialTitanium/Tantalumagilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 42.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

operating life at reference pressure50000 hoursagilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 15. Served to the builder as 135 l/s. Export rule: published nitrogen pumping speed.

starting pressure max≤ 1 x 10^-3 mbaragilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-150-manual-idealvac

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

Read on agilent-vacion-plus-150-manual-idealvac p. 15.

VacIon Plus 75 Noble Diode68 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 °Cagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 4.

cathode materialTitanium/Tantalumagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 17.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16. Served to the builder as 68 l/s. Export rule: published nitrogen pumping speed.

starting pressure max1 x 10^-3 Torragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 13.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

VacIon Plus 55 Noble Diode53 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 °Cagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 4.

cathode materialTitanium/Tantalumagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 17.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16. Served to the builder as 53 l/s. Export rule: published nitrogen pumping speed.

starting pressure max1 x 10^-3 Torragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 13.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

VacIon Plus 40 Noble Diode36 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 °Cagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 4.

cathode materialTitanium/Tantalumagilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 17.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16. Served to the builder as 36 l/s. Export rule: published nitrogen pumping speed.

starting pressure max1 x 10^-3 Torragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 13.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-40-55-75-manual-idealvac

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

Read on agilent-vacion-plus-40-55-75-manual-idealvac p. 16.

VacIon Plus 20 Noble Diode22 l/sN2 speed, down to 1.0e-11 mbaragilent-vacion-plus-20-manual-idealvac+8 parameters

Agilent Technologies Vacuum, ion noble diode.

ambient temp range0 to +85 Cagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 5.

cathode materialTitanium/Tantalumagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

magnet typeFerrite or Sm-Coagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

operating life at reference pressure50000 hoursagilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

Read on agilent-vacion-plus-20-manual-idealvac p. 15. Served to the builder as 22 l/s. Export rule: published nitrogen pumping speed.

starting pressure max≤ 1 x 10^-3 mbaragilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

ultimate pressurestated as a bound< 1 x 10^-11 mbaragilent-vacion-plus-20-manual-idealvac

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

Read on agilent-vacion-plus-20-manual-idealvac p. 15.

TiTan 5S DI2 l/sN2 speed, down to 1.0e-11 mbargamma-titan-5s-datasheet-highvacdepot+9 parameters

Gamma Vacuum, ion noble diode.

bake temp max without magnets450 °Cgamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

cathode material50% Titanium / 50% Tantalum n/agamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

inlet flangeDN 35 (2.75 in.) CFR n/agamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

magnet typerare earth n/agamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

operating life at reference pressure50000 hoursgamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

Read on gamma-titan-5s-datasheet-highvacdepot p. 2. Served to the builder as 2 l/s. Export rule: published nitrogen pumping speed.

starting pressure max0.0001 mbargamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

ultimate pressurestated as a bound≤ 1 x 10^-11 mbargamma-titan-5s-datasheet-highvacdepot

Read on gamma-titan-5s-datasheet-highvacdepot p. 2.

The 6 documents this family reads
  1. agilent-vacion-plus-150-manual-idealvac VacIon Plus 150 pumps Instruction Manual (87-900-102-01 (E)) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-150-Ion-Pumps-Manual.pdf
  2. agilent-vacion-plus-20-manual-idealvac VacIon Plus 20 pumps User Manual (87-900-106-01 (E)) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-Plus-20-Ion-Pumps-Manual.pdf
  3. agilent-vacion-plus-300 VacIon Plus 300 pumps User Manual (87-900-103-01 (F), 05/2011) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-300-Ion-Pumps-Manual.pdf
  4. agilent-vacion-plus-40-55-75-manual-idealvac VacIon Plus 40/55/75 pumps User Manual (87-900-105-01 (E)) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/manuals/Agilent-VacIon-Plus-40-55-75-Ion-Pumps-Manual.pdf
  5. agilent-vacion-plus-500-manual-idealvac VacIon Plus 500 pumps User Manual / 87-900-104-01 (F) Agilent Technologies (mirror: idealvac.com) https://www.idealvac.com/files/ManualsII/Agilent_VacIon_Plus_500_Pumps_Manual.pdf