TOOLS

Claw pumps

10 models in this family, 82 published parameters, each carrying the source key and the page it was read on.

Back to the selector, which answers across all 333 models and 14 families.

GV600 150 l/s Nominal displacement speed drypump-edwards-gv-drystar +7 parameters

Edwards, claw.

ambient temp range 41 to 104°F (5 to 40°C) drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

exhaust pressure max 1.15 bar absolute, 1.15 x 105 Pa drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

inlet flange ISO100 drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

pumping speed nominal 560 m³/h @ 50 Hz, 540 m³/h @ 60 Hz m3h-1 drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar p. 8. Served to the builder as 150 l/s, read from 540 m3h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required 0.41 to 0.54 bar above exhaust back-pressure drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

service interval Every 6 years (overhaul) drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

stages four stage drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

DRYVAC SET 501S 133 l/s Nominal displacement speed, down to 2.0×10⁻³ mbar drypump-leybold-dryvac-pck +8 parameters

Leybold, claw.

ambient temp range 40°C (104°F) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

mass 360 kg (795 lb) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

max inlet pressure continuous 5 mbar (4 Torr) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

noise level 70 dB(A) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

power max 6.2 kW (8.4 hp) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

pumping speed nominal 60 Hz operation: 480 m3 · h -1 (283 cfm); 50 Hz operation: 400 m3 · h -1 (236 cfm) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck. Served to the builder as 133 l/s, read from 480 m3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure restated in a second unit, 1.5x apart 60 Hz operation: ≤2 · 10-3 mbar (1.5 x 10 -3 Torr); 50 Hz operation: ≤3 · 10-3 mbar (2 x 10 -3 Torr), with purge-control plate set for "ETCH" drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

GV410 128 l/s Nominal displacement speed drypump-edwards-gv-drystar +7 parameters

Edwards, claw.

ambient temp range 41 to 104°F (5 to 40°C) drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

exhaust pressure max 1.15 bar absolute, 1.15 x 105 Pa drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

inlet flange ISO100 drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

pumping speed nominal 380 m³/h @ 50 Hz, 460 m³/h @ 60 Hz m3h-1 drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar p. 8. Served to the builder as 128 l/s, read from 460 m3h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required 0.41 to 0.54 bar above exhaust back-pressure drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

service interval Every 6 years (overhaul) drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

stages four stage drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

GV260 88.9 l/s Nominal displacement speed drypump-edwards-gv-drystar +7 parameters

Edwards, claw.

ambient temp range 41 to 104°F (5 to 40°C) drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

exhaust pressure max 1.15 bar absolute, 1.15 x 105 Pa drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

inlet flange ISO100 drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

pumping speed nominal 240 m³/h @ 50 Hz, 320 m³/h @ 60 Hz m3h-1 drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar p. 8. Served to the builder as 88.9 l/s, read from 320 m3h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

purge gas required 0.41 to 0.54 bar above exhaust back-pressure drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

service interval Every 6 years (overhaul) drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

stages four stage drypump-edwards-gv-drystar

Read on drypump-edwards-gv-drystar.

DRYVAC SET 251S 69.4 l/s Nominal displacement speed, down to 2.0×10⁻³ mbar drypump-leybold-dryvac-pck +8 parameters

Leybold, claw.

ambient temp range 40°C (104°F) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

mass 290 kg (640 lb) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

max inlet pressure continuous 5 mbar (4 Torr) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

noise level 65 dB(A) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

power max 3.9 kW (5.3 hp) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

pumping speed nominal 60 Hz operation: 250 m3 · h -1 (147 cfm); 50 Hz operation: 210 m3 · h -1 (124 cfm) drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck. Served to the builder as 69.4 l/s, read from 250 m3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure restated in a second unit, 1.5x apart 60 Hz operation: ≤2 · 10-3 mbar (1.5 x 10 -3 Torr); 50 Hz operation: ≤3 · 10-3 mbar (2 x 10 -3 Torr), with purge-control plate set for "ETCH" drypump-leybold-dryvac-pck

Read on drypump-leybold-dryvac-pck.

DRYVAC 100P 27.8 l/s Nominal displacement speed, down to 1.5×10⁻² mbar drypump-leybold-dryvac-p +9 parameters

Leybold, claw.

ambient temp range 40ºC (104ºF) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

mass 210 kg (463 lbs) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

max inlet pressure continuous 150 mbar (112 Torr) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

noise level 68 dB(A) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

power max 4.0 kW (5.4 hp) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

pumping speed nominal 50 Hz operation: 100 m 3 · h -1 (59 cfm); 60 Hz operation: 100 m 3 · h -1 (59 cfm) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p. Served to the builder as 27.8 l/s, read from 100 m 3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

Read on drypump-leybold-dryvac-p.

ultimate pressure 50 Hz operation: 1.5·10-2 mbar (1.1x10 -2 Torr); 60 Hz operation: 1.5·10-2 mbar (1.1x10 -2 Torr), with purge-control plate set to “ETCH” drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

DRYVAC 100S 27.8 l/s Nominal displacement speed, down to 1.5×10⁻² mbar drypump-leybold-dryvac-s +9 parameters

Leybold, claw.

ambient temp range 40°C (104°F) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

mass 220 kg (485 lb) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

max inlet pressure continuous 150 mbar (112 Torr) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

noise level 68 dB(A) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

power max 4.0 kW (5.4 hp) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

pumping speed nominal 60 Hz operation: 100 m 3 · h -1 (59 cfm); 50 Hz operation: 100 m 3 · h -1 (59 cfm) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s. Served to the builder as 27.8 l/s, read from 100 m 3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

Read on drypump-leybold-dryvac-s.

ultimate pressure 60 Hz operation: ≤1.5 · 10-2 mbar (1.1 x 10 -2 Torr); 50 Hz operation: ≤1.5 · 10-2 mbar (1.1 x 10 -2 Torr) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

DRYVAC 50P 15.3 l/s Nominal displacement speed, down to 4.0×10⁻² mbar drypump-leybold-dryvac-p +9 parameters

Leybold, claw.

ambient temp range 40ºC (104ºF) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

mass 180 kg (397 lbs) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

max inlet pressure continuous 300 mbar (225 Torr) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

noise level 62 dB(A) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

power max 2.8 kW (3.8 hp) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

pumping speed nominal 50 Hz operation: 45 m 3 · h -1 (26.5 cfm); 60 Hz operation: 55 m 3 · h -1 (32.4 cfm) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p. Served to the builder as 15.3 l/s, read from 55 m 3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

Read on drypump-leybold-dryvac-p.

ultimate pressure restated in a second unit, 1.6x apart 50 Hz operation: 4·10-2 mbar (3x10 -2 Torr); 60 Hz operation: 2.5·10-2 mbar (1.9x10 -2 Torr), with purge-control plate set to “ETCH” drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

DRYVAC 50S 15.3 l/s Nominal displacement speed, down to 2.5×10⁻² mbar drypump-leybold-dryvac-s +9 parameters

Leybold, claw.

ambient temp range 40°C (104°F) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

mass 190 kg (419 lb) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

max inlet pressure continuous 500 mbar (375 Torr) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

noise level 64 dB(A) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

power max 3 kW (4 hp) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

pumping speed nominal 60 Hz operation: 55 m 3 · h -1 (32 cfm); 50 Hz operation: 45 m 3 · h -1 (26 cfm) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s. Served to the builder as 15.3 l/s, read from 55 m 3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

Read on drypump-leybold-dryvac-s.

ultimate pressure restated in a second unit, 1.6x apart 60 Hz operation: ≤2.5 · 10-2 mbar (1.9 x 10 -2 Torr); 50 Hz operation: ≤4 · 10-2 mbar (3 x 10 -2 Torr) drypump-leybold-dryvac-s

Read on drypump-leybold-dryvac-s.

DRYVAC 25P 8.3 l/s Nominal displacement speed, down to 4.0×10⁻² mbar drypump-leybold-dryvac-p +9 parameters

Leybold, claw.

ambient temp range 40ºC (104ºF) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

inlet flange DN 63 ISO-K drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

mass 170 kg (375 lbs) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

max inlet pressure continuous 1000 mbar (750 Torr) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

noise level 62 dB(A) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

power max 2.8 kW (3.8 hp) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

pumping speed nominal 50 Hz operation: 25 m3 · h -1 (14.7 cfm); 60 Hz operation: 30 m3 · h -1 (17.7 cfm) drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p. Served to the builder as 8.3 l/s, read from 30 m3 · h -1. Export rule: published nominal displacement speed, species not stated by the manufacturer, multi-regime value, 60 Hz bound selected by export (US mains), the base keeps every regime. Conversion: m3/h to l/s, exact factor 1/3.6.

Read on drypump-leybold-dryvac-p.

ultimate pressure restated in a second unit, 1.6x apart 50 Hz operation: 4·10-2 mbar (3x10 -2 Torr); 60 Hz operation: 2.5·10-2 mbar (1.9x10 -2 Torr), with purge-control plate set to “ETCH” drypump-leybold-dryvac-p

Read on drypump-leybold-dryvac-p.

The 4 documents this family reads
  1. drypump-edwards-gv-drystar A705-74-880 Issue K Original Instruction Manual GV Dry Vacuum Pumps Description Electrical Supply Item Number GV260 Dry Vacuum Pump 380 - 415 V, 50 Hz A705-71-900 Edwards https://www.ptb-sales.com/manuals/edwards/gv-drystar.pdf
  2. drypump-leybold-dryvac-p DRYVAC 25/50/100 P Manual GA 01.414/2.02 English Deutsch - Deutsch DRYVAC P seite 20 Operating Instructions Français GA 01.414/2.02 - 1/97 1 Leybold https://www.ptb-sales.com/manuals/leybold/dryvac-p.pdf
  3. drypump-leybold-dryvac-pck DRYVAC SET Manual GA 01.405/6.02 Leybold https://www.ptb-sales.com/manuals/leybold/dryvac-pck.pdf
  4. drypump-leybold-dryvac-s GA 01.413/1.02 DRYVAC 50 & 100 S Français DRYVAC 50/100 S Manual Contents Page Safety Information Safety Information ...................................................... 2 Leybold https://www.ptb-sales.com/manuals/leybold/dryvac-s.pdf